Decree 141/2012, Annexes 2 to 4: existing dwellings and works
Catalan Decree 141/2012 of 30 October, Annexes 2 to 4: the minimum habitability conditions for pre-existing dwellings built before 11 August 1984 (composition, access, construction, a useful floor area of at least 20 m², rooms and equipment), and the repealed Annex 3 on public endowment dwellings. Annex 4 classifies rehabilitation works on existing buildings into groups A to J and sets, for each group, which annex applies and with which exceptions.
Annex 2. Minimum habitability conditions of pre-existing dwellings built before 11 August 1984
Section 1. Composition
All used or pre-existing dwellings must consist, as a minimum, of a living room, a sanitary room (cambra higiènica) and kitchen equipment.
Section 2. Access
2.1 Access to the dwelling must be through a public space, a common space or a space annexed to the dwelling itself to which access is gained in the same way.
2.2 The access to the dwelling is the door that connects the dwelling with the exterior. This access may not serve as the compulsory access to any premises that are not for the exclusive use of the dwelling itself or communal.
2.3 The access spaces of the building containing the dwelling must have an electric lighting system so that they can be lit when people pass through them.
Section 3. Construction
The construction that forms or affects the dwelling must:
a) Be solid.
b) Prevent damp from seeping through.
c) Be watertight against rainwater.
d) Prevent flooding of the dwelling.
e) Have a floor that can be walked on, both in the dwelling and in its access. The floor must be fully paved, must not be dusty and must not involve any danger to persons. Where there is a difference in level greater than 0.60 m, protective elements or impact-resistant railings must be provided.
Section 4. Interior useful floor area
4.1 The minimum useful floor area of dwellings that are used or pre-existing at the entry into force of this Decree is 20 m².
The interior useful floor area is the area enclosed within the perimeter defined by the inner face of the enclosures of each habitable space. The area occupied by the interior partitions of the dwelling, whether fixed or movable, by structural elements and by ducts or conduits with a horizontal section greater than 0.01 m² shall be excluded from the calculation of useful floor area, as shall the areas of zones with a clear height of less than 1.90 m and the areas of terraces and other exterior elements.
4.2 Exceptionally, dwellings with a minimum useful floor area of between 15 m² and 20 m² are accepted if they were built under a building works licence applied for before 1 February 1984 and have a valid habitability certificate (cèdula d'habitabilitat) obtained before the entry into force of this Decree.
Section 5. Rooms
5.1 The living room is a space for common use which must have a useful floor area of not less than 10 m², with no narrowing in plan of less than 1.40 m except in the passage between the living room and the kitchen; it shall allow a square measuring 2.40 × 2.40 m to be inscribed in it and shall not contain any sanitary appliance.
The living room must have an opening in the façade onto the public space, the block courtyard or a plot courtyard, directly or through a gallery, such that between 0.80 m and 2.00 m in height it has a surface of at least 0.80 m²; the compulsory ventilation of any other room may in no case be provided through the living room. If the opening is onto the plot courtyard, the courtyard shall not have a floor area of less than 4 m² and shall allow a circle of 1.80 m in diameter to be inscribed in it.
If the living-dining room incorporates the space of the kitchen equipment (EMC), the minimum useful floor area shall be 14 m². The open vertical surface connecting these two spaces shall not be less than 1.40 m².
5.2 Bedrooms must have a useful floor area of not less than 5 m² and allow a square measuring 1.80 × 1.80 m in plan to be inscribed in them. They must be capable of being closed off and may not contain any WC, washtub or slop sink, nor the compulsory kitchen or laundry equipment.
Bedrooms must have an opening in the façade onto the public space, the block courtyard or a plot courtyard, directly or through a gallery, such that between 0.80 m and 2.00 m in height they have a surface of at least 0.40 m².
5.3 A gallery is a room with a large window giving directly onto the open air, with a glazed surface of not less than 60 per cent of its façade surface. Its lighting and ventilation surface must not be less than the sum of the lighting and ventilation surfaces of the rooms that open onto the exterior.
5.4 An opening is a door or window that can be opened. The surface of an opening is that of its clear passage or of its translucent surface.
Section 6. Equipment
The minimum equipment with which a dwelling must be provided in order to be habitable must meet the following requirements:
6.1 Have a cold and hot water installation that:
a) Is in good condition.
b) As a minimum, serves the kitchen sink, a washbasin and a shower or bath.
c) If the supply comes from its own source, has a reserve tank of 200 litres.
d) Allows a continuous consumption of 50 litres of water at a temperature of 40 degrees and with a flow of 10 litres per minute.
6.2 Have a waste water disposal system such that:
a) It is in good condition.
b) It connects to all the equipment that requires it.
c) All drains have a trap (siphon) device.
d) If there is a public sewer network in its surroundings, it connects to that network and, if there is none, waste water is not discharged to the exterior unless it has first been treated.
6.3 If the dwelling is located in an urban centre, or can be connected to an external electricity supply network on economic terms similar to those of a dwelling located in the urban centre, it must have an interior installation such that:
a) It has a light point with an independent switch in each room.
b) It has a socket for each item of compulsory equipment.
c) It has two sockets in the living room and in the kitchen, and one in the bedrooms. If the living room contains the kitchen equipment, it must have at least four sockets.
d) It does not involve a risk to persons or disturb the normal operation of other installations.
e) It has, as a minimum, a power control switch (ICP).
6.4 Have sanitary equipment, understood as the sanitary appliances which, with the corresponding running water supply and drainage, are intended for hygiene and bodily evacuation, such that:
a) It consists, as a minimum, of a washbasin, a WC and a shower or bath, in good condition.
b) The WC is included in a sanitary room that can be closed off.
c) The shower or bath has its floor and walls waterproofed up to a height of 2.10 m.
d) The sanitary room has ventilation to the open air, either directly or through a duct in which ventilation is activated mechanically. If the duct is vertical, ventilation may be activated statically.
6.5 Have kitchen equipment installed such that:
a) It consists, as a minimum, of a sink and an electric or gas cooking appliance.
b) It is in a single room.
c) The room in which it is located does not contain any appliance of the sanitary equipment.
d) The room in which it is located has ventilation to the open air, either directly or through a duct in which ventilation is activated mechanically. If the duct is vertical, ventilation may be activated statically.
6.6 Have laundry equipment installed, or allow its direct installation, such that the space provided for it has, as a minimum, a cold water inlet, a drain and a power socket.
Annex 3. Minimum habitability conditions of public endowment dwellings
[Not in force]
Amendment note in the consolidated text: Annex 3 repealed by repealing provision a) of Decree-Law 50/2020 of 9 December on urgent measures to stimulate the development of officially protected housing and of new forms of rental accommodation.
Annex 4. Habitability conditions of dwellings resulting from rehabilitation or major rehabilitation works on an existing building
Section 1. Definitions of the types of intervention in existing buildings
In accordance with article 3.g) and h) of the Right to Housing Act, works on existing residential buildings are classified as rehabilitation and major rehabilitation.
For the purpose of obtaining the habitability certificate, rehabilitation as defined in point 3.g) of that statute also includes the set of works consisting of the remodelling of a building with dwellings whose purpose is to change the floor area used for housing or to change the number of dwellings, and also the remodelling of a building without dwellings whose purpose is to create them.
Section 2. Minimum requirements in interventions on existing buildings
Group A
Interventions: building with demolition of the building while keeping the façades.
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
Group B
Interventions: total change of use of a building (above or below ground level).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2.5.1: a 10 per cent reduction in the floor areas is accepted.
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
Group C
Interventions: change of use of a building ([symbol not legible in the source] 50 per cent of the built floor area above or below ground level).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2 entirely exempt, except 2.2.1.
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
Group D
Interventions: change of use of a building (> 50 per cent of the built floor area above or below ground level).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2.5.1: a 10 per cent reduction in the floor areas is accepted.
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
Group E
Interventions: increase in the number of dwellings by dividing a pre-existing dwelling ([symbol not legible in the source] 50 per cent of all the dwellings).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2 entirely exempt, except 2.2.1.
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
One of the dwellings should be treated as used and comply with Annex 2, except as regards useful floor area: it must have a minimum useful floor area of 36 m².
Group F
Interventions: increase in the number of dwellings by dividing a pre-existing dwelling (> 50 per cent of all the dwellings).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2.1: exempt.
Section 2.5.1: a 10 per cent reduction in the floor areas is accepted.
Section 3.5: minimum of 2.40 m instead of 2.50 m, the rest unchanged.
One of the dwellings should be treated as used and comply with Annex 2, except as regards useful floor area: it must have a minimum useful floor area of 36 m².
Group G
Interventions: increase in the number of storeys of a building and of dwellings (adding storeys to a building).
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2: entirely exempt, except sections 2.1, 2.2 and 2.4 if the total number of storeys is > 2 storeys.
The clear height between floor slabs must be the same as in the other dwellings of the existing building, provided that the minimum habitable height of 2.50 m is maintained.
Group H
Interventions: increase in the useful floor area of an existing dwelling without affecting the structure.
Applicable annex and exceptions: Annex 2 with the following exceptions:
Bedrooms must have a useful floor area of not less than 6 m² (bedroom under Annex 1).
If a (new) bedroom or sanitary room is created, it must comply with sections 3.8 and 3.11 of Annex 1.
Group I
Interventions: increase in the useful floor area of an existing dwelling affecting the structure.
1. Increase in storeys.
2. Increase in floor area on plan.
Applicable annex and exceptions: Annex 1 with the following exceptions:
Section 2: entirely exempt, except sections 2.1, 2.2 and 2.4 if the total number of storeys is > 2 storeys.
CASE I.2 Increase in floor area on plan:
The minimum habitable height may be reduced to the height existing in the dwelling, but the main rooms may not have a clear height between the finished floor and the ceiling of less than 2.20 m.
Group J
Interventions: total redistribution of the interior of the dwelling without changing its floor area.
Applicable annex and exceptions: Annex 2 with the following exceptions:
Bedrooms must have a useful floor area of not less than 6 m² (bedroom under Annex 1).
If a (new) bedroom or sanitary room is created, it must comply with sections 3.8 and 3.11 of Annex 1.
Section 3
The minimum habitability conditions established for each group in section 2 above, including its regime of exceptions, apply directly to any intervention in that group. However, they may be lowered by applying the procedure and requirements established in article 6 of this Decree, in accordance with the principles of flexibility provided for, without going beyond the minimum habitability threshold established in Annex 2, except for those for which the preceding section sets a higher level.
Where this sits
Previous: Annex 1: new dwellings. All translated laws: Spanish laws in English.
Related on voixa.es: Personal tax in Catalonia: both halves of the bill; Spain’s 100% property tax for non-EU buyers: what happened.
Nothing here is advice on your own position, and this reading is not the official text. Neither Spain nor Catalonia publishes an official English version of this decree; where the wording matters to a decision, read it against the Catalan original published in the DOGC.