Catalan Habitability Decree 141/2012, Annex 1: minimum conditions for new dwellings

Catalan Decree 141/2012, Annex 1: the minimum habitability conditions for newly built dwellings. It covers definitions, the requirements for residential buildings (accessibility, access, stairs, lifts, ventilation courtyards, community spaces, telecommunications) and the requirements for each dwelling: minimum area, partitioning, accessibility, ceiling heights, façade, room and kitchen dimensions, bedrooms, ventilation, storage, sanitary fittings, clothes drying and equipment.

Unofficial English translation from the Catalan by Voixa Consultors S.L. Alexander Baranov is responsible for the translation. Source: Decret 141/2012, de 30 d’octubre, pel qual es regulen les condicions mínimes d’habitabilitat dels habitatges i la cèdula d’habitabilitat (DOGC no. 6245, 2 November 2012), consolidated text published on the Portal Jurídic de Catalunya, in force from 12 December 2020, Portal Jurídic ↗. Check wording, figures, dates and legal effect against the Catalan original before relying on this reading. Source snapshot: 10 November 2026. This page: Annex 1, sections 1 to 4. Three pages translate the whole decree except the preamble.

Annex 1. Minimum habitability conditions for new dwellings

Section 1. Definitions

For the purposes of this annex, the following terms mean:

Practicable dwelling (habitatge practicable): a dwelling which, without meeting all the requirements of an accessible dwelling, allows persons with reduced mobility to access and use autonomously the common-use spaces, the bedrooms, the minimum sanitary provision and the kitchen equipment under the conditions defined in section 3.4.

Flexible dwelling: a dwelling designed so as to facilitate its adaptability to the changing needs of the occupants and which remains open to intervention by the users in its partitioning.

Intermediate spaces with the exterior: those which, being located outside the thermal envelope of the interior habitable area and having neither heating nor cooling, can offer a versatile and effective response to thermal or acoustic conditions or to improving the dwelling’s potential for energy saving in the different climatic seasons and orientations. Galleries, enclosed balconies (tribunes), porches and covered terraces are considered intermediate spaces with the exterior.

Mandatory sanitary provision: the set of sanitary fittings that corresponds to a dwelling according to its number of bedrooms.

Façade length: the length obtained by measuring the straight line joining the end points of the portion of façade that bounds the dwelling.

Façade perimeter of the dwelling: the sum of the lengths of each of the façades giving onto an open space, block courtyard or plot courtyard which, as defined by the planning in force in each case, are suitable for meeting the required ventilation and lighting conditions. For portions of façade to be considered different, the lengths of those façades must form an angle with each other of between 60° and 120°, disregarding projecting elements, and in the case of a façade onto a plot courtyard, the façade length is the maximum concave polygon that can be inscribed in plan.

Interior useful floor area: the area enclosed within the perimeter defined by the inner face of the enclosures of each habitable space. Excluded from the computation of useful floor area is the area occupied by the dwelling’s interior partitions, whether fixed or movable, by structural elements and by ducts or conduits with a horizontal section greater than 0.01 m², as well as the area of zones with a clear height of less than 1.90 m under a horizontal ceiling or of less than 1.50 m in under-roof spaces with a slope equal to or greater than 45°. Where the dwelling extends over more than one floor, even if there are mechanical means of circulation, the floors must always be connected by an interior staircase, and the area occupied by the interior staircase shall be counted as useful floor area.

Direct light (llums directes): in common-use spaces (except kitchens) and in bedrooms, any point of their mandatory opening to the exterior must have a view, within an angle of 90° whose bisector is perpendicular to the façade, of a horizontal segment of 3 m placed parallel to the façade at a distance of 3 m. Buildings located in old urban centres with streets less than 3 m wide are excluded from this requirement. In that case the resulting direct light must be justified.

Section 2. Habitability requirements for residential buildings

2.1 Accessibility.

All new multi-family buildings, and those resulting from the conversion of an existing building and from major rehabilitation works affecting the building as a whole, must have an accessible route giving access to each of the dwellings. Exceptionally, in cases of technical impossibility where the existing surroundings do not allow it, a practicable route must be guaranteed, or sufficient space must be provided so that the support products needed to have such routes can be installed in the future.

2.2 Access and common circulation spaces.

2.2.1 Access to the dwelling must be through a public-use space, a common space or a space annexed to the dwelling itself to which access is gained in the same way.

2.2.2 The common spaces in front of the lift door must allow a circle of 1.50 m in diameter to be inscribed. Exceptionally, and only where there is no accessible dwelling, in buildings of up to ground floor plus two storeys (PB+2) this space may allow a circle of 1.20 m to be inscribed.

2.3 Stairs.

The number, dimensions, ventilation and characteristics of stairs must comply with the basic requirements of the specific regulations on safety in case of fire and on safety of use and accessibility of residential buildings laid down by the legislation in force.

2.4.1 Lift.

a) New multi-family buildings must have a lift if they are not directly accessible to persons with reduced mobility, except in the cases of technical or economic impossibility regulated in the following paragraphs. For these purposes, the dwellings on the access floor are not counted in determining whether a building is multi-family.

b) Exceptionally, in buildings with up to 4 dwellings, not counting those located on the ground floor, and with a difference in level between the entrance level of the building and the access to any dwelling equal to or less than 8 m (PB+2), the lift may be replaced by a provision of space allowing its later installation, leaving a shaft with minimum dimensions of 1.60 m × 1.60 m (single entry, or double entry at 180°) or 1.90 m × 1.60 m (double entry at 90°), and the project must provide for the connection with the common areas and the dwellings in accordance with the accessibility code in force.

c) Likewise, in buildings with a maximum of two dwellings on floors other than the access floor of the property, the space provision may be for installing a lifting platform instead of a lift. In this case a shaft with minimum dimensions of 1.50 m × 1.50 m must be provided to house a vertical lifting platform, or a staircase with a minimum width of 1.20 m along its entire length to allow an inclined lifting platform. The design of the spaces and elements of the common area and the layout of doors must provide for the continuity of the platform’s guide rail.

In the cases of space reserved for the lift or for the lifting platform provided for in paragraphs b) and c), the developer must record this in the deed establishing the community regime (títol constitutiu del règim de comunitat) so that, if installation of the element is later decided, it is not necessary to amend that deed.

d) On sites in consolidated urban land with a façade length of less than 6.5 m and up to a maximum of PB+2, the solutions described in point C may be applied even if the building has more than two dwellings.

2.4.2 Second lift.

New residential buildings must have at least two lifts where any of the following cases applies:

Up to PB+3 with more than 32 dwellings above PB.

PB+4 with more than 28 dwellings above PB.

PB+5 with more than 26 dwellings above PB.

PB+6 with more than 24 dwellings above PB.

PB+7 with more than 21 dwellings above PB.

PB+8 with more than 16 dwellings above PB.

PB+9 or higher regardless of the number of dwellings.

2.5.1 Ventilation courtyards.

Courtyards shall allow a circle of 3 m in diameter to be inscribed in plan where they ventilate bedrooms, and of 2.5 m in diameter where they ventilate kitchens, bathrooms or stairs, and their minimum areas shall be 9 m² and 6 m² respectively, which must be increased by 1.80 m² and 0.90 m² respectively for each storey added to the 3 storeys of courtyard height. A circle of 1.80 m in diameter shall be accepted for ventilating and lighting stairwells and sanitary rooms up to a maximum of 3 storeys in height, the diameter being increased by 0.10 m for each storey added.

Courtyards higher than two storeys must have an air intake from the exterior, located between their lower part and the first floor slab immediately above, with a minimum area of 1/100 of the area of the courtyard.

The above conditions are minimums, without prejudice to ordinances, planning rules or fire safety rules establishing more demanding ones on a mandatory basis.

Courtyards covered by a skylight must have an air outlet at the top with an area of no less than 2/3 of their area in plan.

2.5.2 Ventilation courtyards, or courtyards related to the use of the dwelling, may not be used for the direct ventilation of communal car parks or of premises with industrial or noisy activities, unless this is done through ducts up to the roof or the end of the roof is above the highest part of the building; the areas of such ducts shall not count for the purposes of the minimum courtyard area even if the ducts are not installed. The ducts must be protected to prevent any kind of leak or bad smell that could affect the ventilation courtyard.

2.6 Community facilities.

Multi-family buildings with 8 or more dwellings must have a space, per building or staircase, for the use of the community, accessible from the exterior or from common areas, of at least 1.20 m × 0.80 m and with a height of no less than 2.20 m. From 12 dwellings per building or staircase it shall be increased at a rate of 0.05 m² for each additional dwelling, and the space may also be arranged as a room if it is more than 1.20 m wide. These spaces must have a drain, a light point and a water point.

This minimum community-facility space may be increased in accordance with municipal ordinances to serve other uses.

In the absence of specific municipal regulation, the space provided for by other applicable regulations for storing waste containers shall be deemed replaced by the areas provided for in this section for community uses.

2.7 Common telecommunications infrastructure.

Residential buildings must have a common telecommunications infrastructure, in accordance with the legislation in force on this matter.

Section 3. Habitability requirements for dwellings

3.1 Habitability and occupancy.

All dwellings must consist of at least a living space (estança) or living-dining room, a sanitary room and kitchen equipment, and have an interior useful floor area of no less than 36 m². Where the living space is a single space, it must allow a bedroom of 8 m² to be partitioned off, without the living room or the bedroom losing their mandatory requirements.

3.2 Sustainability and energy saving.

Dwellings must be designed to take advantage of the natural conditions of the climate. In particular, they shall have architectural elements which, taking into account the interior-exterior relationship, provide a sustainable response to climatic requirements; to this end they must comply with the legislation in force on energy efficiency.

3.3 Partitioning.

3.3.1 The partitioning of the dwelling shall be free, with the sole limitation that the spaces intended for bedrooms can be made independent and that those intended for sanitary rooms are separate enclosures.

3.3.2 The partitioning of the dwelling may be designed on flexible criteria, provided that the following remain unaltered, in accordance with the original technical project: the mandatory fixed provision consisting of the kitchen equipment and the sanitary rooms, the elements that have a structural function or are common elements of the building, and those that form the enclosure with the exterior.

3.3.3 No space in the dwelling may serve as the mandatory access to any premises that is not for the exclusive use of the dwelling itself.

3.3.4 Sanitary rooms may not serve as a mandatory passage to the other rooms making up the dwelling. The washbasin may be installed in a circulation space without that space being regarded as a sanitary room.

3.4 Accessibility.

3.4.1 Dwellings must be at least practicable and must meet the following conditions:

3.4.1.a) If the dwelling is on a single level, the following spaces must be practicable: the access, one sanitary room, the kitchen, one common-use space and one bedroom.

3.4.1.b) If the dwelling is on different levels, the following spaces must be practicable: the access, one sanitary room, the kitchen and one common-use space or one bedroom.

3.4.1.c) The entrance door of the dwelling and the doors of the practicable spaces must have a minimum clear passage width of 0.80 m and a minimum clear height of 2 m.

3.4.1.d) Interior circulation spaces connecting the access to the dwelling with the practicable spaces must have a minimum width of one metre (1 m) and allow a circle of one metre twenty centimetres (1.20 m) to be inscribed in front of the doors giving access to the practicable spaces, the 1.20 m circle being permitted to be inscribed with the doors open; and 0.90 m for the other circulation spaces giving access to the non-practicable spaces of the dwelling.

3.4.1.e) In the practicable spaces it must be possible to inscribe a circle of one metre twenty centimetres in diameter (1.20 m), clear of the swing of the doors and of fixed equipment up to 0.70 m in height (sanitary fittings and furniture). The interior routes of these spaces must have a minimum clear passage width of 0.80 m.

3.4.1.f) Where the practicable sanitary room has a shower flush with the floor, its area shall count for the purpose of allowing the 1.20 m turning circle.

3.4.2 The doors giving access to the interior spaces of the dwelling that are not practicable must have a minimum clear passage width of 0.70 m and a minimum clear height of 2 m.

3.4.3 The minimum clear width of interior stairs within a single dwelling shall be 0.90 m. They shall have non-climbable handrails at least 0.90 m high.

3.5 Minimum habitable height.

The clear height between the finished floor and the ceiling must be at least 2.50 m.

In sanitary rooms, kitchens and circulation spaces, this height shall not be less than 2.20 m.

In the dining room, living room and bedrooms, a height of 2.30 m shall exceptionally be accepted for the technical passage of installations and for structural elements that do not affect more than 20% of the area of the room. In the case of sloping roofs, the average value of the minimum height must not be less than 2.50 m, calculated over the habitable area.

3.6 Minimum façade.

3.6.1 All dwellings must have at least one façade open to the free exterior space of the building, defined as such in the relevant planning, whether that space is public or private. This façade must provide ventilation and lighting to at least one of the spaces of the dwelling’s common-use area (EM), which may not be solely the kitchen where the kitchen is a separate room.

3.6.2 The minimum façade perimeter required of dwellings (L) is determined according to their useful floor area (S) and may not be less than the ratio S/9 measured in linear metres.

3.6.3 In a dwelling extending over different floors, the façade lengths of each level at which the floor slab meets the façade shall be counted.

In the case of a floor with a mezzanine that has no direct openings to the exterior and is separated from the façade by a double-height space, the useful floor area of the mezzanine floor shall not be counted for the computation of the dwelling’s façade perimeter if the requirement to have the mandatory rooms is met on the lower floor.

3.7.1 Common-use spaces (EMC): living + dining + kitchen.

[No longer in force]

Amendment note in the consolidated text: Annex 1, section 3.7.1 repealed by repealing provision a) of Decree-Law 50/2020 of 9 December on urgent measures to stimulate the development of officially protected housing and of new forms of rental accommodation.

3.7.2 Dimensions of the common-use spaces.

The space containing the living room (E) and/or the dining room (M) must allow a circle with a diameter of two metres eighty centimetres (2.80 m) to be inscribed between walls. In this space, the contact with the façade shall have a minimum width of two metres twenty centimetres (2.20 m), with no narrowings in plan of less than one metre sixty centimetres (1.60 m), except for pillars; zones of lesser width that adjoin it, such as entrance halls, corridors or similar, even if they have no door, shall not be counted as useful floor area of common-use spaces.

3.7.3 Dimensions of the kitchen.

In the kitchen, the free space between the worktop and the rest of the equipment or the walls must have a minimum width of one metre (1.00 m), without prejudice to section 3.4.1.e). These conditions must be guaranteed whether the kitchen is a separate room or integrated with EM.

Where the kitchen space is integrated into the dining area (M) or the living-dining area (EM), the open vertical surface connecting these spaces must not be less than three and a half square metres (3.50 m²).

3.8 Bedrooms.

The minimum bedroom shall be 6 m² and smaller areas shall not be accepted.

Unless municipal regulations lay down higher requirements, in dwellings with three or more bedrooms it must be possible to inscribe a square with sides of 2.60 m in at least one of the bedrooms. In the other bedrooms, and in dwellings with up to 2 bedrooms, it must be possible to inscribe a square with sides of 2.00 m.

In these bedrooms, the 2.60 m and 2.00 m squares may not be encroached on by the swing of the doors or by the space intended for storage, and only localised reductions of 0.30 m for pillars shall be accepted, provided they do not alter the normal arrangement of the beds; all these circumstances must be shown graphically in the project.

3.9 Natural ventilation and lighting.

3.9.1 Common-use spaces and bedrooms must have direct natural ventilation and lighting from the exterior through openings with an area of no less than 1/8 of their useful floor area, counted between 0 and 2.5 m in height above the floor.

3.9.2 For the purpose of calculating the ventilation and lighting area, intermediate spaces are regarded as exterior spaces.

3.10 Storage spaces.

3.10.1 Each bedroom must include an individual storage space, which shall be drawn on the plan so that it can be checked. The space it occupies shall count for the purposes of the minimum area if it is located inside the bedroom. The space shall have a minimum depth of 0.60 m and a height of 2.20 m, and a length of 1 m in the case of a bedroom of more than 6 m² and of 1.5 m if the bedroom is of more than 8 m².

3.10.2 In the case of built-in wardrobes, the space of the doors and frames within the 0.6 m depth shall count as useful floor area. Divided spaces shall be accepted provided they have a minimum width of 0.30 m. Heights lower than those laid down shall be accepted, with a minimum of 1.50 m, provided the width is increased so as to obtain the equivalent volume laid down.

3.11 Sanitary rooms.

3.11.1 All dwellings must have at least a provision of fittings intended for hygiene in accordance with the following table:

3.11.2 The fittings intended for hygiene shall be located in the sanitary rooms and their grouping is free, except for the washbasin, which may be located outside them.

3.12 Space for washing clothes.

If the washing machine is integrated in a sanitary room, it shall be regarded as fixed provision for the purposes of compliance with the accessibility conditions for persons with reduced mobility.

3.13 Clothes-drying area.

3.13.1 All dwellings must provide a solution for the natural drying of clothes, except where this is impossible as a result of regulations or municipal ordinances, which must be demonstrated. In those cases mechanical drying must be provided.

3.13.2 This space intended for the natural drying of clothes shall have a permanent ventilation system, shall be screened from view from the public space and shall not interfere with the direct light of any opening needed for the lighting or ventilation required for the common-use spaces or the bedrooms.

3.13.3 In addition to the ventilation courtyards regulated in section 2.5.1, there may be courtyards intended for hanging out clothes, provided their dimensions allow a circle of 1.80 m in diameter to be inscribed. They may ventilate and light stairwells and sanitary rooms.

3.13.4 Clothes-drying areas may also be communal, covered or uncovered, and in all cases screened from view from the public space.

3.13.5 Where the common clothes-drying space serves an accessible dwelling, its accessibility must be guaranteed. If the common drying space is on the roof of the building, it shall not be necessary to extend the lift or lifting platform up to it if another system is provided inside the dwelling or in the common areas of the building (mechanical drying, drying room, etc.).

3.14 Intermediate spaces with the exterior.

If the intermediate spaces with the exterior are enclosed, they must have a glazed area of no less than 60% of their façade area. The lighting and ventilation area must not be less than the sum of the lighting and ventilation areas of the rooms that open onto the exterior.

3.15 Provision/equipment.

All dwellings must have:

a) Cold and hot water services, drainage and electricity, in accordance with the legislation in force, with the building connected to the public service networks, except for the individual meters needed by the end user.

b) Sanitary equipment consisting of at least a washbasin, a WC and a shower.

c) Kitchen equipment consisting of at least a sink and a cooking appliance, and having a specific mechanical extraction system above the cooking appliance, connected so as to allow steam and smoke to be extracted up to the roof.

d) The complete installation for clothes-washing equipment.

e) An electronic entry phone or similar system that facilitates entry and allows interactive communication from the building entrance with any dwelling.

f) A system of access to telecommunications services so that the dwelling can have at least the services specified in the regulations governing common telecommunications infrastructures.

3.16 Protective elements of the dwelling.

Differences in level of more than 0.55 m must be protected by protective elements or impact-resistant railings.

Section 4

All new dwellings must also meet the requirements laid down in Annex 2 that are not specifically regulated in this Annex 1.